News

MA series firmware v1.13 upgrade is available

Version 1.13 of MA series firmware is available to upgrade your MA200, MA300, and MA350 devices. This update improves WiFi reliability and fixes a bug in the auto start settings.

The previous firmware release, v1.12, added source apportionment calculations and data, smoothed output for UV, Blue and IR channels, and WiFi capabilities to wirelessly transmit data to AethLabs' servers to retrieve via our dashboard or API.

Other features firmware and client application includes:

  • Optimized, faster flow calibration routine with improved pump compatibility
  • LCD display has new information on top-line of the screen, displays attenuation, tape advance trigger attenuation and tape position as well as date and time
  • New 170mlpm flow setting for compatibility with microCyclone 170
  • New tape replacement workflow with tape position tracking
  • Fix BAD DATA IDs error
  • Fix missing altimeter data when operating on battery power
  • Improved communications with external Alicat flowmeters
  • Fixed erroneous tape jam messages during tape advance
  • Allow 0 flow rate setting
  • Ability to access database data without instrument being connected to microAeth Manager
  • Updates to the data output columns
  • Miscellaneous bug fixes, speed, stability, and user interface improvements

Download microAeth Manager and MAx firmware

Product tag: 
MA200
MA300
MA350

microAeth Manager v1.6 released

AethLabs has made available an updated version of the microAeth Manager software for both Windows and macOS which is required to make use of the new features released with the 1.12 version of the MA series firmware.

Notable additions or changes for version 1.6:

Support for all new features in the concurrent MAx v1.12 firmware release. This update supports the new Source Apportionment implementation using the Aethalometer model to distinguish between biomass and traffic emissions. Beta support of the built-in WiFi interface allowing data streaming to AethLabs' server as well as a new 170 ml/min flow setting option to support the microCyclone 170.

Download microAeth Manager and MAx firmware

Product tag: 
MA200
MA300
MA350

MA series firmware v1.12 upgrade is available

A new version of MA series firmware is available to upgrade your MA200, MA300, and MA350 devices. This update provides new source apportionment calculations and data, smoothed output for UV, Blue and IR channels, and WiFi capabilities to wirelessly transmit data to AethLabs' servers to retrieve via our dashboard or API.

In addition, this new version of firmware and client application includes:

  • Optimized, faster flow calibration routine with improved pump compatibility
  • LCD display has new information on top-line of the screen, displays attenuation, tape advance trigger attenuation and tape position as well as date and time
  • New 170mlpm flow setting for compatibility with microCyclone 170
  • New tape replacement workflow with tape position tracking
  • Fix for BAD DATA IDs error
  • Fix missing altimeter data when operating on battery power
  • Improved communications with external Alicat flowmeters
  • Fixed erroneous tape jam messages during tape advance
  • Allow 0 flow rate
  • Ability to access database data without instrument being connected to microAeth Manager
  • Updates to the output columns
  • Miscellaneous bug fixes, speed, stability, and user interface improvements

Read the upgrade instructions

Product tag: 
MA200
MA300
MA350

MA series firmware v1.10 is available

A new version of the firmware for MA series devices (MA200, MA300, and MA350) is now available for download and provides additional preventative measures to address a very rare corruption of some device settings.

microAeth Manager v1.03 is required to make use of most of the new features released in this firmware.

Notable additions or changes for version 1.10:
In some instruments a rare bug has occurred that causes some settings corruption. Firmware v1.09 added additional checks and redundancies to address the issue. The improvements in this new release, version 1.10, provide further safeguards to prevent this issue.

We strongly recommend update as soon as possible to avoid any possible settings corruption.

Read the upgrade instructions

Product tag: 
MA200
MA300
MA350

MA series firmware v1.09 is available

A new version of the firmware for MA series devices (MA200, MA300, and MA350) is now available for download and addresses a very rare corruption of some device settings.

microAeth Manager v1.03 is required to make use of most of the new features released in this firmware.

Notable additions or changes for version 1.09:
In some instruments a rare bug has occurred that causes some settings corruption. This corruption does not affect stored measurement data. This new firmware v1.09 adds additional checks and redundancies to address the issue.

We strongly recommend update as soon as possible to avoid any possible settings corruption.

Read the upgrade instructions

Product tag: 
MA200
MA300
MA350

MA series firmware v1.08 is available

A new version of the firmware for MA series devices (MA200, MA300, and MA350) is now available for download and adds new Flow settings, AutoSample, and Serial options in additional other optimizations, improvements, and bug fixes.

microAeth Manager v1.03 is required to make use of most of the new features released in this firmware.

Notable additions or changes for version 1.08:

  • New 75 ml/min and 125 ml/min flow setting options
  • New External control option in the AutoSample setting that allows instrument to start automatically when power is connected and to shutdown when power is removed
  • New Polled option in Serial data mode setting that provides Bayern Hessen and remote control support
  • New Serial Baud rate setting
  • New skip tape advance option
  • New Flow test menu on device UI
  • Ability to output only the Flow calibration table view new "Display FlowCal info" menu item
  • Improvements to GPS time sync functionality
  • Improvements to flow calibration procedure and output format
  • Additional power consumption optimizations

Read the upgrade instructions

Product tag: 
MA200
MA300
MA350

microAeth Manager v1.03 released

AethLabs has made available an updated version of the microAeth Manager software for both Windows and macOS which is required to make use of the new features released with the 1.08 version of the MA series firmware.

Notable additions or changes for version 1.03:

  • Support for all new features in the concurrent MAx v1.08 firmware release (including new flow setting options, new serial settings, ability to skip tape advance, a new AutoSample external control option, and new flow test and flow calibration table output features)
  • Harmonization of data headers for Serial Verbose data output and CSV output formats
  • Human readable status codes are now output in last column of CSV output
  • Columns in CSV file output that displayed as “undefined” when in SingleSpot mode have been removed
  • Manage data window now displays number of data points stored on device
  • Additional bug fixes, language clarification, and UI improvements

Upgrade microAeth Manager here

Product tag: 
MA200
MA300
MA350

MA series firmware v1.07 is available

A new version of the firmware for MA series devices (MA200, MA300, and MA350) is now available for download. Upgrading to this version allows for the use of the DualSpot® loading compensation method which corrects for the optical loading effect and provides additional information about aerosol optical properties.

microAeth Manager v1.02 is required for MA series instruments running MA series firmware v1.07. The MA Series Flow Calibration Kit is required for the upgrade to firmware v1.07.

Notable additions or changes for version 1.07:

  • DualSpot® loading compensation beta release
  • Improved flow measurement and flow calibration
  • Improved optical calibration
  • Exposed optical calibration menu
  • On-board user interface improvements
  • On-board LCD messaging updates and improvements
  • Tape advance system improvements
  • Real time clock timestamp bug fix
  • Manual time synchronization
  • GPS speed now calculated
  • Additional system checks before starting measurements
  • Other bug fixes

Read the upgrade instructions

Product tag: 
MA200
MA300
MA350

microAeth Manager v1.02 released

AethLabs has made available an updated version of the microAeth Manager software for both Windows and macOS which is required to make use of the new DualSpot® loading compensation released with the 1.07 version of the MA series firmware.

Notable additions or changes for version 1.02:

  • DualSpot® loading compensation release - toggle between SingleSpot™ and DualSpot®
  • Check for available software updates of application added to Application Info window
  • Data export file headers updated
  • Data export file formatting of Optical config column data
  • Data export file GPS speed fixed
  • Data export file bug fixes
  • Data export file App version column added
  • User interface improvements
  • Toggle to display time in application in 24 hour format
  • Time Options window improvements
  • GPS time synchronization option added
  • Application time synchronization added
  • Visual indicator in Vital Signs menu of whether GPS satellite sync is on
  • Other bug fixes

Upgrade your device firmware and microAeth Manager here

Product tag: 
MA200
MA300
MA350

Introducing the microAeth® MA series Black Carbon monitors

AethLabs is pleased to announce its new line of aerosol Black Carbon monitors. The MA series consists of three new products to complement the microAeth® AE51 personal exposure monitor for Black Carbon. This new series of instruments boasts many advanced features integrated into compact, lightweight form factors.

The new full spectrum MA series continuously collects aerosol particles on a filter and measures optical absorption at 5 wavelengths spanning UV - IR at up to a 1hz data rate. These new devices use a miniature tape transport mechanism and easy-to-exchange filter cartridge for the automatic advance of filter tape material, enabling unattended operation from multiple weeks to a year, depending on the model and environmental factors. The multi-wavelength spectrum measurement provides insight into the composition of light absorbing carbonaceous particles and helps to distinguish among the different optical signatures of various combustion sources such as diesel, biomass, and tobacco. The instruments support the DualSpot® loading compensation method which corrects for the optical loading effect and provides additional information about aerosol optical properties.

Wireless communications are provided for network or smartphone app integration and connection to other wireless health and environmental sensors. The USB data connection provides communication with the new cross-platform microAeth® Manager software available on macOS and Windows. A dedicated serial data port is provided for streaming data to data loggers or direct integration with other microcontroller host systems. 

Key features:

  • Lightweight, compact and ultra-portable 
  • 5 Wavelengths IR - UV at 880 nm, 625 nm, 528 nm, 470 nm, 375 nm
  • Automatic Tape Advance: 15 or 85 sampling locations
  • Up to 1 year of sampling per cartridge, depending on model and environmental conditions
  • Hardware supports DualSpot® loading compensation method
  • Easy to replace filter tape cartridge
  • GPS with internal antenna
  • Satellite time synchronization / ISO 8601 format
  • USB, Serial, WiFi, Bluetooth Low Energy
  • Internal rechargeable lithium-ion battery
  • Selectable integration timebase of 1, 5, 10, 30, 60, 120, 300 seconds
  • Internal pump with closed loop flow control: 50-200 ml/min
  • 3-axis Accelerometer
  • Temperature and Relative Humidity
  • Altimeter / Barometer
  • Internal memory capable of multiple years of storage

This new MA series of devices will be shipping in a first release, January 2017.

We are anticipating high demand. To secure priority delivery in the first release, you can ensure your place in the pre-order queue with a deposit.

Recommended applications, comparisons between each microAeth® monitor, and more info is available here.

For a quotation click here.

If you'd like to see one of these devices in person, AethLabs will be present at the following upcoming conferences / trade shows:

Patents pending. DualSpot® is a trademarked name used under license from Magee Scientific Corporation.

Product tag: 
MA200
MA300
MA350

Pages