microAethalometer™ / MA600
Tech specs
- Measurement Method
- Real-time Aethalometer® method, 5 wavelength absorption analysis by measuring the rate of change of transmitted light due to continuous particle deposition on filter. Measurement at 880 nm interpreted as concentration of Black Carbon (‘BC’). Measurement at 375 nm interpreted as Ultraviolet Particulate Matter (‘UVPM’) indicative of woodsmoke, tobacco, and biomass burning.
- Measurement Wavelengths
- 880 nm, 625 nm, 528 nm, 470 nm, 375 nm
- DualSpot® Loading Compensation
- Real-time analysis by measuring the rate of change in absorption of transmitted light due to the continuous collection of aerosol on filter. Simultaneous collection on two spots in parallel at different flow rates.
- Timebases
- 1, 5, 10, 30, 60, or 300 seconds
- Flow Rates
- Internal long life brushless diaphragm pump provides 100, 125, 150, 170, 200, 225, 250, 275, or 300 ml/min.
- Measurement Range
-
Per sampling location, 0-1 mg BC/m3, filter sampling location
lifetime dependent on concentration and flow rate setting, decreasing
proportionally with lowest wavelength optical source enabled:
IR only mode, average 5 μg BC/m3 for 24 hours at 100 ml/min
IR only mode, average 100 μg BC/m3 for 3 hours at 50 ml/min
IR only mode, average 1 mg BC/m3 for 15 minutes at 50 ml/min - Measurement Resolution
- 0.001 μg BC/m3
- Limit of Detection
- 30 ng BC/m3, 5 min timebase., 150 ml/min flow rate, SingleSpot ™
- Pump Options
- Internal long life brushless diaphragm pump
- Flow Control
- Internal mass flowmeters with closed-loop control
- Filter Material / Capacity
- MA600/MA350/MA300 Filter Tape Cartridge with Polytetrafluoroethylene (PTFE) material (85 sampling locations)
- Sampling
- 3 mm diameter spot(s) created on filter tape. User selectable DualSpot ® or SingleSpot™ mode.
- Aerosol Conditioning
- Optional Internal Nafion Aerosol Dryer - uses internal vacuum pump in reflux configuration to dry inlet sample air stream
- Environmental Sensors
- Relative Humidity, Temperature, Altimeter/Barometer
- Dimensions
- 3U 19 inch rack mount enclosure, W: 482.6 mm (19.0 in), H: 133.35 mm (5.25 in), D: 203.2 mm (8.0 in)
- Weight
- 5 kilograms (11.02 pounds)
- Memory
- 16 GB internal flash memory, providing storage for 31,250,000 data lines; 1 second timebase: 361 days of data.
- On-board Interface
- Low power screen, 3 buttons
- Date/Time Format
- ISO 8601 with manual computer synchronization
- Connections
- DB9 RS232 connector, 3.3V TTL Serial (Flow Calibration Communication), USB 2.0, M8 DC Power input connector, Quick Connect 6.35 mm (0.25 in) O.D. Tubing Aerosol sample inlet and outlet ports
- USB Communications / Client Application
- USB connectivity to cross-platform microAeth® Manager software available on macOS® and Windows®. microAeth Manager software is included and facilitates settings configuration and data download.
- Serial Communication
- DB9 connector with RS232 communication for streaming data and polling protocols to request data, modify settings and control. Command line interface (CLI) polling protocols: AethLabs protocol and Bayern-Hessen protocol., 3.3V TTL serial connectivity for uploading new instrument firmware, flow calibration.
- Power
- M8 12V Power In Power Supply Adapter: Input: 100~240 VAC 50/60Hz 0.4A, Output: 12VDC / 2A, with territory-specific Type A, C, G, or I plug
- Operating Environment
- 5 ~ 40 °C operating, non-condensing.
- Included
-
- microAeth MA600
- 1 MA600/MA350/MA300 Filter Tape Cartridge
- M8 12V AC adapter with territory-specific plug
- USB communication cable
- Cross-platform microAeth® Manager software and manual available for download via AethLabs website
- Accessories & Consumables
-
- MA600/MA350/MA300 Filter Tape Cartridge
- MA Series Flow Calibration Kit
- microCyclone™ 170 PM2.5 Size-selective Inlet
- Serial to USB converter cable
- DB9 RS232 Serial to bare leads cable
- Internal Aerosol Dryer
- Inlet Protection Kit
Specifications are subject to change without notice. microAeth MA Series products are protected by patent #8,411,272. Additional patents pending. Aethalometer® and DualSpot® are trademarks of Magee Scientific Corp. used under license.